摘要:为提高三维荧光光谱水质分析的精度,提出一种选择性模型组合方法,采用相关系数法对三维荧光光谱激发波长进行选择,并将被选中的激发波长下的荧光发射光谱水质分析子模型采用岭回归法进行模型组合,得到对水质指标的组合模型.以一组总有机碳(TOC)范围在3.41~125.35 mg·L~(-1),化学需氧量(COD)范围在22.80~330.60 mg·L~(-1)的32个地表水和城市生活污水水样做为研究对象,对其三维荧光光谱220~400胁范围内的10个激发波长采用上述方法进行选择,分别针对TOC和COD指标筛选出260,280,400 nm和220,280,400 nm各3个激发波长.采用部分最小二乘方法建立上述激发波长下荧光发射光谱水质分析子模型,根据岭回归法计算各子模型的组合系数,分别得到对TOC和COD指标的组合模型.实验结果表明:采用该方法得到的组合模型对TOC和COD两种指标的预测误差均方根(RMSEP)相比精度最高的单一荧光发射光谱子模型分别减小了15.4%和17.5%,相比未经模型选择的组合模型分别减小了6.1%和10.9%.Abstract:A selective model combination method is proposed in this paper to improve the precision of water quality analysis with three dimensional fluorescence spectra. A correlation coefficient criterion was designed to select effective excitation wavelengths for sub-models building, based on which the ridge regression method was adopted to combine the selected sub-models to get the stacked model Thirty two samples from surface water and urban wastewater were used as research objects with total organic carbon (TOC) index from 3. 41 to 125. 35 mg·L~(-1) , and chemical oxygen demand (COD) index from 22.80 to 330. 60 mg·L~(-1) , and 10 excitation wavelengths in the range of 220-400 nm were adopted to generate three dimensional fluorescence spectra. Following the proposed correlation coefficient criterion, the excitation wavelengths of 260, 280 and 400 nm, and the excitation wavelengths of 220, 280 and 400 nm were selected respectively for TOC analysis and COD analysis, based on which two stacked models were built by using partial least square regression method for sub-models building and ridge regression method for sub-models combination. The experimental results show that, compared with the sub-models with the best prediction precision, the root mean square errors of prediction (RMSEP) of the stacked models decreased by 15.4% for TOC analysis, and 17.5% for COD analysis; and compared with the models without sub-models selection, the RMSEP of the stacked models decreased by 6.1% for TOC analysis and 10.9% for COD analysis. 作者: 武晓莉[1]李艳君[2]吴铁军[3] Author: WU Xiao-li[1]  LI Yan-jun[2]  WU Tie-jun[3] 作者单位: 浙江科技学院,浙江,杭州,310023浙江大学城市学院,浙江,杭州,310015浙江大学工业控制技术国家重点实验室,浙江,杭州,310027 期 刊: 光谱学与光谱分析   ISTICEISCIPKU Journal: SPECTROSCOPY AND SPECTRAL ANALYSIS 年,卷(期): 2010, 30(4) 分类号: X832 O657.3 关键词: 三维荧光光谱    模型组合    激发波长选择    模型选择    总有机碳    化学需氧量    Keywords: 3-D fluorescence spectra    Model combination    Excitation wavelength selection    Model selection    Total organic carbon    Chemical oxygen demand    机标分类号: TN2 O65 机标关键词: 选择性    模型组合    三维荧光光谱    水质分析    分析方法    Combination    Model    Based    Fluorescence Spectra    quality analysis    regression method    correlation coefficient    激发波长    荧光发射光谱    three dimensional    组合模型    子模型    TOC    fluorescence    COD 基金项目: 国家(863计划)项目

【基于选择性模型组合的三维荧光光谱水质分析方法】相关文章:

基于三维荧光光谱技术的多组分分析浓度校准方法研究04-27

基于叶绿素荧光光谱分析的黄瓜霜霉病害预测模型05-07

基于Bayes方法的诊断模型分析04-26

石化废水的三维荧光光谱特征05-07

基于标识指数法的水质灰色动态模型群预测分析04-25

藻类的三维荧光光谱辨别及算法研究05-02

三维荧光光谱法分析西宁环境水样有机污染类型04-26

双交组合农艺性状的ADAA模型及其分析方法05-02

太湖水荧光光谱分析04-30

甲醇和乙醇的三维荧光光谱特性研究05-07