Simulation Analysis of Indoor Gas Explosion Damage
The influence factors and process of indoor gas explosion are studied with AutoReaGas explosion simulator. The result shows that venting pressure has great influence on the indoor gas explosion damage. The higher the venting pressure is, the more serious the hazard consequence will be. The ignition location has also evident effect on the gas explosion damage. The explosion static overpressure would not cause major injury to person and serious damage to structure in the case of low venting pressure (lower than 2 kPa). The high temperature combustion after the explosion is the major factor to person injury in indoor gas explosion accidents.
作 者: 钱新明 陈林顺 冯长根 作者单位: State Key Laboratory of Explosion and Safety Science, Beijing Institute of Technology, Beijing 100081, China 刊 名: 北京理工大学学报(英文版) EI 英文刊名: JOURNAL OF BEIJING INSTITUTE OF TECHNOLOGY 年,卷(期): 2003 12(3) 分类号: X928.03 关键词: indoor gas explosion explosion simulation explosion overpressure high temperature combustion【Simulation Analysis of Indoor Gas Ex】相关文章: